Heavy-Duty Diesel Generators & Power Infrastructure

Direct OEM export of certified 20 kVA to 1,000 kVA generator sets powered by authentic Perkins (UK), Volvo Penta (Sweden), and Baudouin (France) engines, alongside high-voltage DIN/EN certified transformer accessories. Shipped directly from Turkey to GCC, Middle East, Africa, and Europe.

20–1000

kVA Power

Tier 1

Perkins & Volvo

68 dBA

Silent Canopy

TSE & CE

ISO 9001:2015
Supply Chain & OEM References:
Siemens Energy
GE Vernova
Hitachi Energy
ABB Power
Eaton
Schneider Electric
TEI Aerospace
POWER GENERATION PORTFOLIO

Engineered for Harsh Desert & Tropical Duty

Continuous prime power and emergency standby solutions with 50°C tropical ambient radiators and heavy vibration isolation.

Perkins Powered Genset Perkins UK · 20 - 1000 kVA

Perkins Power Series

The world's gold standard for prime and standby duty. Exceptional fuel economy, proven durability in extreme heat, and universal parts availability worldwide.

  • Engine Origin: United Kingdom (UK)
  • Power Range: 20 kVA to 1,000 kVA
  • Alternator: Stamford / Mecc Alte (Brushless)
  • Controller: Deep Sea Electronics (DSE)
  • Canopy Noise: 68 dBA @ 7m (Soundproof)
Inquire Quote
Volvo Penta Diesel Genset Volvo Penta · 90 - 700 kVA

Volvo Penta Premium Series

High-tech Swedish electronic fuel injection. Fast transient load response designed specifically for hospitals, data centers, and mission-critical towers.

  • Engine Origin: Sweden (EU)
  • Power Range: 90 kVA to 700 kVA
  • Emission Standard: Stage II / Stage III
  • Radiator: Heavy-Duty 50°C Tropical
  • Runtime: 8–12 Hours Base Fuel Tank
Inquire Quote
Baudouin France Diesel Genset Baudouin · 30 - 1500 kVA

Baudouin Marine Durability Series

Over 100 years of French marine engineering. Unrivaled continuous prime duty for remote construction camps, mining sites, and utility substations.

  • Engine Origin: France
  • Power Range: 30 kVA to 1,500 kVA
  • Alternator: Stamford / Leroy Somer
  • Canopy Steel: Galvanized, Electrostatic Powder
  • Lifting: Crane Eye & Forklift Pockets
Inquire Quote
Ricardo Value Line Genset Ricardo · 25 - 350 kVA

Ricardo Commercial Value Series

Maximum return on investment for rental fleets and commercial standby power. Combines Turkish assembly quality with ultra-competitive pricing.

  • Configuration: Canopied or Open-Skid
  • Power Range: 25 kVA to 350 kVA
  • Frequency: 50 Hz (1500 RPM) / 60 Hz (1800 RPM)
  • Controller: Datakom Smart AMF
  • Price Advantage: Best Cost-Per-kVA Ratio
Inquire Quote
Containerized Power Station Containerized · 750 - 2500 kVA

Containerized Multi-Megawatt Power

ISO 20ft & 40ft custom acoustic container power modules with synchronized load-sharing panels for grid substations and giga-infrastructure projects.

  • Enclosure: ISO 20ft / 40ft High Cube Container
  • Sync Panel: Automatic Synchronization & Sharing
  • Fire System: Clean-Agent Gas Suppression
  • Attenuation: 35 dBA Residential Silencers
  • Applications: Mining, Utilities, Data Centers
Inquire Quote
Acoustic Soundproof Canopy Detail Acoustic Engineering

Custom Weatherproof Canopies

Manufactured in-house using CNC laser sheet fabrication. Class A1 non-combustible sound acoustic insulation foam with IP54 weather protection.

  • Paint: Epoxy Powder Coating (500h Salt Spray)
  • Acoustic Foam: Non-flammable Rockwool Insulation
  • Access: Lockable Flush Doors with View Window
  • Fuel Tank: Integrated Bunded Base Tank with Sump
Inquire Quote
ENGINEERING TOOLS

Quick Genset Sizing & Fuel Calculator

Estimate your required electrical output, prime kW, and approximate fuel consumption based on load.

Select Target Power Output

Drag slider to estimate prime output, fuel burn rate, and recommended powerplant.

Selected Rating:
250 kVA
Request Quote for 250 kVA Model
Standby Power (ESP): 275 kVA
Prime Power (PRP): 200 kW (0.8 PF)
Est. Fuel Consumption (75% Load): ~38.5 L/hr
Est. 8-Hour Shift Consumption: ~308 Liters
Recommended Engine Options: Perkins 1106A / Baudouin 6M16
Standard Alternator: Stamford / Mecc Alte (4-Pole)
QUALITY ASSURANCE

100% Factory Load-Bank Testing Protocol

Every generator set undergoes a rigorous 4-stage quality test at our Tuzla factory before packaging and shipment.

1

Static Pre-Inspection

Full insulation megger testing, DC control harness verification, fluid leak pressure checks, and mechanical alignment inspection.

2

Step Load Response

Sudden 50% and 75% load step acceptance tests to measure transient voltage dip (AVR response) and governor frequency recovery.

3

100% Prime Load Test

Full-load continuous thermal test using inductive/resistive load banks. Exhaust temperatures and oil pressures logged under full load.

4

110% Overload & Acoustic

1-hour 110% overload safety test plus calibrated 7-meter decibel sound level verification. Official signed Test Certificate included.

LOGISTICS & DELIVERIES

Fast Global Ocean & Overland Export Routes

Strategic maritime logistics departing weekly from Istanbul ports (Ambarli / Marport / Kumport) to major regional gateways.

🇸🇦

Saudi Arabia

9 – 14 Days Transit

Direct ocean freight to Dammam Port & Jeddah Islamic Port. SASO compliant submittals.

🇦🇪

United Arab Emirates

10 – 15 Days Transit

Regular container service to Jebel Ali Port, Dubai. Fast customs clearance paperwork.

🇮🇶

Iraq & Levant

4 – 8 Days Transit

Overland TIR truck transport via Habur border gate or direct sea shipment to Umm Qasr Port.

🇳🇬

Africa & Europe

12 – 22 Days Transit

Direct routes to Alexandria, Lagos (Apapa), Mombasa, plus short-sea routes to Rotterdam & Genoa.

ENGINEERING SUBMITTALS & DOCUMENTATION

Download ASKGEN Technical Catalogs

Comprehensive technical specifications, dimensional drawings, alternator curves, and controller manual submittals.

📄
2026 OFFICIAL EXPORT EDITION

ASKGEN Diesel Generators Technical Catalog

Complete specs for Perkins, Volvo Penta, Baudouin & Ricardo gensets (20–1000 kVA). PDF • 4.8 MB

Download Catalog (PDF)
COMMONLY ASKED QUESTIONS

Export & Procurement FAQs

Clear answers to commercial terms, certifications, warranty coverage, and shipment processes.

What engine and alternator brands do you use? ▼
We assemble genuine, brand-new engines from tier-1 manufacturers including Perkins (United Kingdom), Volvo Penta (Sweden), and Baudouin (France), alongside our heavy-duty commercial Ricardo series. Every set is coupled with authentic brushless Stamford, Mecc Alte, or Sincro alternators with Class H insulation.
What are your standard delivery and manufacturing lead times? ▼
Standard canopied units (20 kVA to 500 kVA) are frequently available ex-stock from our Tuzla facility within 7 to 14 days. Custom project builds, open-skid sets, and synchronized containerized power modules typically require 3 to 4 weeks production time before vessel loading.
What warranty coverage is included? ▼
All ASKGEN generator sets include a comprehensive 2-Year or 1,000 Operating Hours global manufacturer warranty (whichever comes first). Authentic OEM warranty certificates and serial numbers are provided with each unit.
What export shipping documents do you provide? ▼
We supply complete international trade documentation: Commercial Invoice, Packing List, Original Bill of Lading (B/L), Certificate of Origin (or EUR.1 for tariff concessions), CE Declaration of Conformity, and the signed Factory Load-Bank Test Certificate.
What commercial payment terms are accepted? ▼
We standardly work on Telegraphic Transfer (T/T: 30% advance on order confirmation, 70% against Bill of Lading copy prior to vessel arrival) and Irrevocable Confirmed Letter of Credit (L/C at sight) issued by recognized international banks.
DIRECT FACTORY PRICING

Request an Official Factory FOB / CIF Quote

Submit your project requirements below. Our export sales desk will provide technical data sheets and an official proforma quote within 4 to 8 hours.

💬